This function inputs/outputs safety-related signals through a redundant terminal. If a signal that is different from the redundant safety input or output signal is detected, the system determines whether it is a short circuit or hardware defect and stops the robot with STO Stop Mode. To set the Safety I/O, go to the Robot Workcell and select Robot > Safety I/O.
-
Safety Input Setting
|
Signal Name |
Description |
|---|---|
|
Emergency Stop (L) |
It is an interface to receive emergency stop signal from peripheral device, or connect additional emergency stop switches.
|
|
Emergency Stop – No Loopback (L) |
It is an interface to receive emergency stop signal from peripheral device, or connect additional emergency stop switches. This signal doesn’t activate ‘Emergency Stop – excl. No Loopback Input’ safety outp
|
|
Protective Stop (L) |
It can be linked with Safeguarding Devices such as safety matts, light curtains and laser scanners.
|
|
Protective Stop – STO (L) |
|
|
Protective Stop – SS1 (L) |
|
|
Protective Stop – SS2 (L) |
|
|
Protective Stop(L) - Auto Reset & Resume (R) |
Unlike the other Protective Stop, Interrupted state can be reset and automatic operation can be resumed automatically by this signal. This enables automatic restart after Safety-rated Monitored Stop described in ISO TS 15066.
Resuming automatic operation without manual intervention can be dangerous,
|
|
Interlock Reset (R) |
It is used to reset the Interrupted state by Protective Stop
|
|
Reduced Speed Activation (L) |
|
|
3 Pos Enable Switch (H) |
This is operation permission equipment that is used to connect a three-position enabling switch.
|
|
Handguiding Enable Switch (H) |
It is an operation permission signal used to connect a hand guide switch.
|
|
HGC End & Resume (R) |
It is used to resume task program execution after operator’s HandGuiding Control(HGC) in Auto Mode
|
|
Safety Zone Dynamic Enable (H) |
It is available that activating/deactivating Space Limit and/or Zone dynamically.
|
|
Safety Zone Dynamic Enable (L) |
It is available that activating/deactivating Space Limit and/or Zone dynamically.
|
|
Remote Control Enable (L) |
Used to enable the Remote Control Mode.
|
-
Safety Output Setting
|
Signal Name |
Description |
|---|---|
|
Emergency Stop (L) |
It is used to notify that emergency stop is required to peripheral devices, such situation as - Emergency Stop Button is pushed on robot accessories (Teach pendant, Smart Pendant, Emergency Button Box) - Emergency Stop from the dedicated Safety Input - Emergency Stop (L) from the configurable Safety Input - Emergency Stop – No Loopback(L) from the configurable Safety Input.
|
|
Emergency Stop – excl. No Loopback Input (L) |
It is used to notify that emergency stop is required to peripheral devices, such situation as - Emergency Stop Button is pushed on robot accessories (Teach pendant, Smart Pendant, Emergency Button Box) - Emergency Stop from the dedicated Safety Input - Emergency Stop (L) from the configurable Safety Input The case of Emergency Stop – No Loopback(L) from the configurable Safety Input is EXCLUDED. Deadlocks can be avoided by not sending back the emergency stop signal to the peripheral device that originally sending emergency stop signal to robot.
|
|
Safe Torque Off (L) |
|
|
Safe Operating Stop (L) |
|
|
Abnormal (L) |
|
|
Normal Speed (L) |
|
|
Reduced Speed (L) |
|
|
Auto Mode (L) |
|
|
Manual Mode (L) |
|
|
Remote Control Mode (L) |
|
|
Standalone Zone (L) |
|
|
Collaborative Zone (L) |
|
|
High Priority Zone (L) |
|
|
Tool Orientation Limit Zone (L) |
|
|
Designated Zone (L) |