Breadcrumbs

Basic Welding Condition Settings

image2022-1-21_16-54-18.png

No.

Item

Description

1

Voltage

Enter the voltage output target of the welding machine within the max./min. range. (V)

2

Feeding Speed

(WF Speed)

Enter the wire feeding speed target within the max./min. range.

(m/min)

3

Estimated Current

Enter the estimated current generated at the set target voltage and feeding speed target. The entered value is only used for heat input calculation and is not reflected in the actual welding condition.

4

Movement Speed

Enter the movement speed of the robot during welding. The unit is cm/min.