1.33 1.32 1.31 1.30 1.29 1.28 1.20 Korean English Chinese Czech Dutch French German Hungarian Italian Japanese Polish Portuguese Spanish
1.33 1.32 1.31 1.30 1.29 1.28 1.20 Korean English Chinese Czech Dutch French German Hungarian Italian Japanese Polish Portuguese Spanish

struct.ADJUST_WELDING_SETTING

This structure contains information for adjusting welding settings.

  • _bRealTime indicates whether real-time adjustment is enabled. A value of 0 means preset mode, and a value of 1 means real-time adjustment mode.

  • _bResetFlag indicates the reset flag. A value of 0 means to maintain the current value, and a value of 1 means to reset to the set value.

  • _fTargetVol, _fTargetCur, and _fTargetVel represent the target voltage, target current, and target speed, respectively.

  • _fOffsetY and _fOffsetZ represent the weaving Y offset and weaving Z offset, respectively.

  • _fWidthRate represents the weaving width rate.

BYTE#

Member Variable

Data Type

Value

Description

0

_bRealTime

unsigned char

0 or 1

Real-time adjustment status (0: Preset, 1: Real-time)

1

_bResetFlag

unsigned char

0 or 1

Reset Flag ( 0: Maintain Current Value, 1: Reset)

2

_fTargetVol

float


Target Voltage

6

_fTargetCur

float


Target Current

10

_fTargetVel

float


Target Speed

14

_fOffsetY

float


Weaving Y Offeset

18

_fOffsetZ

float


Weaving Z Offset

22

_fWidthRate

float


Weaving Width Rate