1.33 1.32 1.31 1.30 1.29 1.28 1.20 Korean English Chinese Czech Dutch French German Hungarian Italian Japanese Polish Portuguese Spanish
1.33 1.32 1.31 1.30 1.29 1.28 1.20 Korean English Chinese Czech Dutch French German Hungarian Italian Japanese Polish Portuguese Spanish

struct.CONFIG_DIGITAL_WELDING_IF_MAPPING_DATA

This structure is used to configure mapping data for the digital welding interface.

  • The _bEnable member variable indicates whether the mapping data is enabled. 0 means disabled, 1 means enabled.

  • The _nDataType member variable specifies the data type. 0 means On/Off signal, 1 means value.

  • The _nPositionalNumber member variable specifies the positional number of the data. 0 means 1, 1 means 0.1, 2 means 0.001.

  • The _fMinData and _fMaxData member variables represent the minimum and maximum data values, respectively.

  • The _nByteOffset and _nBitOffset member variables represent the byte offset and bit offset, respectively.

  • The _nComnDataType member variable specifies the communication data type.

  • The _nMaxDigitSize member variable represents the maximum digital value.

BYTE#

Member Variable

Data Type

Value

Description

0

_bEnable

unsigned char

0 or 1

Enabled status (0: Disabled, 1: Enabled)

1

_nDataType

unsigned char

0 or 1

Data type (0: On/Off, 1: Value)

2

_nPositionalNumber

unsigned char

0, 1, or 2

Positional number (0: 1, 1: 0.1, 2: 0.001)

3

_fMinData

float


Minimum data

7

_fMaxData

float


Maximum data

11

_nByteOffset

unsigned char


Byte offset

12

_nBitOffset

unsigned char


Bit offset

13

_nComnDataType

unsigned char

0 ~ 7

Communication data type (0: 1-bit (Disable Low), 1: 1-bit (Disable High), 2: 2-bit, 3: 4-bit, 4: 8-bit, 5: 15-bit, 6: 16-bit, 7: 32-bit)

14

_nMaxDigitSize

unsigned char


Maximum digital value