This structure contains data for forcibly outputting digital welding signals.
-
The
_bForceWritemember variable indicates whether forced output is enabled. 0 means disabled, and 1 means enabled. -
The
_iForceDatamember variable represents the data value to be forcibly output. -
The
_iTargetOutputmember variable specifies the target for the forced output. 1 to 4 represent digital outputs (DO), 5 to 6 represent analog outputs (AO), 7 represents a synergic signal, and 8 represents an error signal..
|
BYTE# |
Member Variable |
Data Type |
Value |
Description |
|---|---|---|---|---|
|
0 |
|
unsigned char |
0 or 1 |
Forced output status (0: Disabled, 1: Enabled) |
|
1 |
|
unsigned char |
0 or 1 |
Forced output data |
|
2 |
|
unsigned char |
1 ~ 8 |