1.33 1.32 1.31 1.30 1.29 1.28 1.20 Korean English Chinese Czech Dutch French German Hungarian Italian Japanese Polish Portuguese Spanish
1.33 1.32 1.31 1.30 1.29 1.28 1.20 Korean English Chinese Czech Dutch French German Hungarian Italian Japanese Polish Portuguese Spanish

struct.CONFIG_ANALOG_WELDING_SETTING

This structure contains analog welding configuration information.

  • The _iVirtualWelding member variable sets the virtual welding mode. A value of 0 means actual welding, and a value of 1 means virtual welding.

  • The _fTargetVoltage, _fTargetCurrent, and _fTargetVel member variables set the target voltage, target current, and target speed, respectively.

  • The _fMinVel and _fMaxVel member variables set the minimum speed and maximum speed, respectively.

  • The _tDetail member variable is a structure that contains detailed welding configuration information.

  • The _fRs, _fTss, _fTas, _fTwc, _fRf, _fTaf, and _fTsf variables represent the start rate, shielding gas release time, start current time, welding condition change time, end rate, end current time, and end shielding gas release time, respectively.

  • The _fStartVoltage and _fEndVoltage variables represent the start voltage condition and end voltage condition, respectively.

  • The _fTargetFeedingSpeed member variable sets the target feeding speed.

BYTE#

Member Variable

Data Type

Value

Description

0

_iVirtualWelding

unsigned char

0 or 1

0: Real Welding

1: Virtual WElding

1

_fTargetVoltage

float


Target Voltage

5

_fTargetCurrent

float


Target Current

9

_fTargetVel

float


Target Speed(mm/sec)

13

_fMinVel

float


Minimum Speed

17

_fMaxVel

float


Maximum Speed

21

_tDetail._fRs

float


Start Rate

25

_tDetail._fTss

float


Shielding Gas Release time(sec)

29

_tDetail._fTas

float


Start Current Time (sec)

33

_tDetail._fTwc

float


Welding Condition changed time(sec)

37

_tDetail._fRf

float


Terminate Ratio

41

_tDetail._fTaf

float


Terminate Current Time (sec)

45

_tDetail._fTsf

float


Terminated shielding Gas Release time(sec)

49

_tDetail._fStartVoltage

float


Start Voltage Condition

53

_tDetail._fEndVoltage

float


Terminate Voltage Condition

57

_fTargetFeedingSpeed

float


Target Feeding Speed