Item |
Description |
|---|---|
|
Modbus Address |
It selects the predefined Modbus address. The IP address and name configured by the user for the Modbus slave equipment are displayed. To add new items, go to Setting > Network > Predefined Modbus menu, and configure. |
|
Connect |
Equipment is connected to the selected Modbus address, and buttons used to test gripper motion are activated. |
|
Initialize |
This performs gripper reset. |
|
Teaching Pose |
The gripper position when the corresponding workpiece is grasped. It can be configured from a minimum of 0.00 mm to a maximum of 20.00 mm. |
|
Tolerance |
This is the teaching pose tolerance deviation. It can be configured from a minimum of 0.00 mm to a maximum of 2.55 mm. |
|
Force |
This is the force the gripper applies to grasp an item. It can be configured from Lv1 up to Lv4. |
|
Device Mode |
This is the pose when the gripper grasps an item. Select one from inward, outward and universal. |
|
Actual Position |
It is the area displaying the current position measured through the gripper’s grasp/release motion tests. |
|
Add New Workpiece |
A new workpiece can be added. Up to 32 workpieces can be added. |
|
Gripper Status |
This is the input signal for the gripper’s status code. The following are the meanings of each status code. 0x06: Gripper PLC Active, 0x08: Base Position, 0x09: Teach Position, 0x0a: Work Position, 0x0b: Undefined Position, 0x0c: Data transfer ok, 0x0d: ControlWord 0x100, 0x0e: ControlWord 0x200, 0x0f: Error |
|
Diagnosis |
This is the input signal for the gripper’s diagnosis code. |
This Workcell item is an electric gripper operated with Modbus TCP. The following list contains skills and commands that can be used in conjunction .
-
Grasp
-
Release
-
Pick
-
Place
-
Pick Pallet
-
Place Pallet
-
Insert